Cc: | "Zhijie Hou (Fujitsu)" <houzj(dot)fnst(at)fujitsu(dot)com>, shveta malik <shveta(dot)malik(at)gmail(dot)com>, Masahiko Sawada <sawada(dot)mshk(at)gmail(dot)com>, Ajin Cherian <itsajin(at)gmail(dot)com>, Dilip Kumar <dilipbalaut(at)gmail(dot)com>, Nisha Moond <nisha(dot)moond412(at)gmail(dot)com>, "Hayato Kuroda (Fujitsu)" <kuroda(dot)hayato(at)fujitsu(dot)com>, Bertrand Drouvot <bertranddrouvot(dot)pg(at)gmail(dot)com>, Bharath Rupireddy <bharath(dot)rupireddyforpostgres(at)gmail(dot)com>, Peter Eisentraut <peter(dot)eisentraut(at)enterprisedb(dot)com>, Bruce Momjian <bruce(at)momjian(dot)us>, Ashutosh Sharma <ashu(dot)coek88(at)gmail(dot)com>, Andres Freund <andres(at)anarazel(dot)de>, pgsql-hackers <pgsql-hackers(at)postgresql(dot)org>, Alvaro Herrera <alvherre(at)alvh(dot)no-ip(dot)org> |
Subject: | Re: Synchronizing slots from primary to standby |
Date: | 2024-03-04 03:57:44 |
Message-ID: | CAHut+Pu5XHr=8e6m+2QMK3c1BJZ-wcoirmLeMtHZzhQRzvshbA@mail.gmail.com |
Views: | Raw Message | Whole Thread | Download mbox | Resend email |
Thread: | |
Lists: | pgsql-hackers |
On Mon, Mar 4, 2024 at 2:49 PM Amit Kapila <amit(dot)kapila16(at)gmail(dot)com> wrote:
>
> On Mon, Mar 4, 2024 at 7:25 AM Peter Smith <smithpb2250(at)gmail(dot)com> wrote:
> >
> >
> > ======
> > doc/src/sgml/config.sgml
> >
> > 2.
> > + <function>pg_logical_slot_peek_changes</function></link>,
> > + when used with failover enabled logical slots, will block until all
> > + physical slots specified in <varname>standby_slot_names</varname> have
> > + confirmed WAL receipt.
> >
> > /failover enabled logical slots/failover-enabled logical slots/
> >
>
> How about just saying logical failover slots at this and other places?
>
Yes, that wording works too.
----------
Kind Regards,
Peter Smith.