On Fri, Feb 25, 2011 at 9:14 AM, Daniel Farina <daniel(at)heroku(dot)com> wrote:
>
> Right now, as it stands, the syncrep patch will be happy as soon as
> the data has been fsynced to either B or A-prime; I don't think we can
> guarantee at any point that A-prime can become the leader, and feed B.
>
- start A` up, replicating from A
- shutdown B (now A nad A` are synchronous)
now real quick:
- shut down A
- shut down A`
-change configuration
-start up A`
-start up B
Doesn`t this work?