From: | Leif Biberg Kristensen <leif(at)solumslekt(dot)org> |
---|---|
To: | pgsql-general(at)postgresql(dot)org |
Subject: | Re: Resetting serial type after "delete from table" |
Date: | 2010-05-08 08:30:20 |
Message-ID: | 201005081030.21034.leif@solumslekt.org |
Views: | Raw Message | Whole Thread | Download mbox | Resend email |
Thread: | |
Lists: | pgsql-general |
On Saturday 8. May 2010 10.11.32 John Gage wrote:
> If I "delete from table", which table contains a serial type field,
> and then insert new rows into the table "excluding the [serial] column
> from the list of columns in the INSERT statement", the numbers in the
> serial column resume where they left off prior to the "delete from
> table": 639, 640, 641, 642 for example.
>
> This behavior is totally acceptable, but is it possible to have the
> serial column reset itself to 1 following "delete from table" (i.e.
> following flushing all the rows from the table)? The only way I can
> think to do this is by altering the table by dropping the serial
> column and then altering it again by adding a new serial column before
> doing the insert. That is only a couple of more lines of script, so I
> don't do the work, but is there an easier way?
http://www.postgresql.org/docs/current/static/datatype-numeric.html#DATATYPE-
SERIAL
http://www.postgresql.org/docs/current/static/functions-sequence.html
regards,
--
Leif Biberg Kristensen
http://solumslekt.org/blog/
From | Date | Subject | |
---|---|---|---|
Next Message | John Gage | 2010-05-08 08:48:12 | Re: Resetting serial type after "delete from table" |