Tom Lane escribió:
> BTW, if an autovac worker gets an elog(ERROR) on one table, does it die
> or continue on with the next table?
It continues with the next table if interrupted (SIGINT), but the worker
exits on any other error. I would ask you to review that code -- it's
in do_autovacuum, the PG_TRY block at the end. It was committed in rev
1.52 of autovacuum.c.
--
Alvaro Herrera http://www.advogato.org/person/alvherre
"We are who we choose to be", sang the goldfinch