From: | <noreply(at)pgfoundry(dot)org> |
---|---|
To: | noreply(at)pgfoundry(dot)org |
Subject: | [ psqlodbc-Bugs-1003103 ] copy_and_convert_field(...) destroys bind info for wide char varchar columns |
Date: | 2007-04-23 01:30:28 |
Message-ID: | 20070423013028.1DD9E21732F@pgfoundry.org |
Views: | Raw Message | Whole Thread | Download mbox | Resend email |
Thread: | |
Lists: | pgsql-odbc |
Bugs item #1003103, was opened at 2007-04-15 14:39
You can respond by visiting:
http://pgfoundry.org/tracker/?func=detail&atid=538&aid=1003103&group_id=1000125
Category: None
Group: None
Status: Open
Resolution: None
Priority: 3
Submitted By: Thomas Zehbe (thomasz)
Assigned to: Nobody (None)
Summary: copy_and_convert_field(...) destroys bind info for wide char varchar columns
Initial Comment:
I'm using psqlodbc 08.02.0200 on SuSE Linux 9.3, Postgres 8.0.1 with libiodbc 3.52.5 and wxWidgets.
psqlodbcs config params are:
./configure --enable-pthreads --enable-unicode --with-iodbc CFLAGS="-ggdb -O0
The problem occured is that for varchar colums an insert is possible up to the max length, but an update only up to the count of characters of the value wich was last read.
F. E. a colum containg "12345" can't be updated to "12345aaa". It's always cut to "12345".
I found that ResolveOneParam(...) sets "used" to the number of last readed chars, instead of SQL_NTS (in fact "-3"). So on update only this number of chars is converted.
At the end of copy_and_convert_field I Found this statement:
if (pcbValue)
*((SQLLEN *) pcbValueBindRow) = len;
During the first read *pcbValue is "-3" for SQL_NTS columns, but the assignment sets it to the count of chars read.
I changed it to
if (pcbValue)
if (*pcbValue >= 0)
*((SQLLEN *) pcbValueBindRow) = len;
so SQL_NTS is retained in *pcbValue.
Now update works
Regards,
Thomas
----------------------------------------------------------------------
>Comment By: Hiroshi Inoue (hinoue)
Date: 2007-04-23 01:30
Message:
> Is it according to the specs that *pcbValueBindRow==
SQL_NTS when entering copy_and_convert_field and is
set to the number of SQL_WCHARs just read before exiting?
Please note pcbValue(BindRow) is an output parameter not
an i-o one.
ISTM the proper way is to call SetNullColNull() when the
column buffers are changed or change the column contents
via SetColumn() function.
regards,
Hiroshi Inoue
regards,
Hiroshi Inoue
----------------------------------------------------------------------
Comment By: Thomas Zehbe (thomasz)
Date: 2007-04-22 12:06
Message:
There's no answer from wxList until now.
I did a further examination. When I define a tables column
using SetColDefs() for this column a wxDbColDefs object is
initialized. In case of type varchar the public member
"CbValue" of this object is set to -3 (SQL_NTS).
I put a watchpoint in gdb on this addess, and found that it
is only changed by convert.c in the statement mentioned
when I openend this track item, as (SQLLEN *)
pcbValueBindRow in facts points to this adress.
Does this behaviour proves an incorrect use of psqlodbc? Is
it according to the specs that *pcbValueBindRow==SQL_NTS
when entering copy_and_convert_field and is set to the
number of SQL_WCHARs just read before exiting?
Regards,
Thomas
----------------------------------------------------------------------
Comment By: Thomas Zehbe (thomasz)
Date: 2007-04-19 07:13
Message:
Many thanks for your hint!
I put your information immediately on the wxList and will
explore the problem myself, too. Maybe it'll take some time
as I'm a bit under pressure actually.
I'll report the results.
Thanks again and regards,
Thomas
----------------------------------------------------------------------
Comment By: Hiroshi Inoue (hinoue)
Date: 2007-04-19 02:30
Message:
AFAIC it's not the problem of psqlodbc driver.
I found a similar report at
http://lists.wxwidgets.org/archive/wx-users/msg20409.html
.
Hmm it was more than 4 years ago. Was it solved ?
regards,
Hiroshi Inoue
----------------------------------------------------------------------
Comment By: Thomas Zehbe (thomasz)
Date: 2007-04-18 10:24
Message:
Sorry for racting late. But I didn't get an email notifier.
Seems that I have to take a look.
I'n not sure what you mean with ODBC API sequences. So let
me give a first try. I attach a file with an code example.
The lines which provide the buffer on a per column base look
like that:
SetColDefs (idx++, wxT("prodbezeichnung"),
DB_DATA_TYPE_VARCHAR, b.prodbezeichnung, SQL_C_WXCHAR,
sizeof(b.prodbezeichnung),FALSE,TRUE);
It is the wxWidget interface defined as
wxDbTable::SetColDefs(). I provide only a single buffer for
every column. I believe that wxWidgets handles the param
buffers. It must be the case when I use a where clause typed
as a string.
In wxDbTable::Open() wxWidgets first (indirectly) calls
PGAPI_BindParameter for every column wich should be read and
afterwords for every column wich should be updatable.
In my apps typically all coulumns are readable, but not all
are updatebale (primary key and all columns in a view wich
don't belong to the 'main' tabkle are not updatetable.
Hope this gives a first hint what happens.
Thanks and regards
Thomas
----------------------------------------------------------------------
Comment By: Hiroshi Inoue (hinoue)
Date: 2007-04-16 23:43
Message:
Hmm don't use the same buffers for both columns and
parameters ? If so, please treat them carefully.
regards,
Hiroshi Inoue
----------------------------------------------------------------------
Comment By: Hiroshi Inoue (hinoue)
Date: 2007-04-16 04:04
Message:
Could you tell me the ODBC API sequences in your app ?
regards,
Hiroshi Inoue
----------------------------------------------------------------------
You can respond by visiting:
http://pgfoundry.org/tracker/?func=detail&atid=538&aid=1003103&group_id=1000125
From | Date | Subject | |
---|---|---|---|
Next Message | Sean Murphy | 2007-04-23 21:47:43 | URGENT Numeric values disappear |
Previous Message | Karim Elsaid | 2007-04-22 17:56:32 | ODBC issue |