Hi,
On Wed, Jun 21, 2017 at 9:50 AM, Amit Kapila <amit(dot)kapila16(at)gmail(dot)com> wrote:
> On Wed, Jun 21, 2017 at 12:15 AM, Peter Eisentraut
> <peter(dot)eisentraut(at)2ndquadrant(dot)com> wrote:
>> On 6/20/17 09:23, Amit Kapila wrote:
>>> To avoid that why can't we use the same icu path for executing uconv
>>> as we are using for linking?
>>
>> Yeah, you'd need to use prefix $self->{options}->{icu} . '\bin\uconv' or
>> something like that.
>>
>
> That's what I had in mind as well.
>
Okay, attached is the patch which first detects the platform type and
runs the uconv commands accordingly from the corresponding icu bin
path. Please have a look and let me know for any issues. Thanks.
--
With Regards,
Ashutosh Sharma